Ecut 400S PLUS

Ecut 400S PLUS

electrosurgical unit

Ecut 400S PLUS is an advanced electrosurgical unit, which enables the surgeon to perform mono and bipolar simultaneously in a wide range of applications such as: ambulatory surgery, endoscopy, first aid, gastroenterology, general surgery, gynecology, neurosurgery, otorhinolaryngology, orthopedics, pediatric surgery, plastic surgery, pneumology, urology and vascular surgery.

General
Patient circuit  F
Selectable input voltage 115 – 230 Vac
Mains frequency 50 – 60 Hz
Electrical power input 1000 VA
Dimensions 470x150x400 WxHxD mm
Weight 17,5 Kgs
Controls
Automatic power or TACS – Tissue Adaptive Contact System) Monopolar CUT mode until 100 Watt
Controls Patient/Plate circuit monitoring
Output power monitoring
Automatic self test
H.F. Leakage currents control
Compensation of mains fluctuation
Power outputs
Maximum output power monopolar pure CUT 400 W – 300 Ω
Maximum output power monopolar cut-coag. CUT80% 300 W – 300 Ω
Maximum output power monopolar cut-coag. CUT60% 250 W – 300 Ω
Maximum output power monopolar cut-coag. CUT40% 200 W – 300 Ω
Maximum output power monopolar cut ENHANCED 250 W – 500 Ω
Maximum output power monopolar cut-coag. BLEND 250 W – 300 Ω
Maximum output power monopolar coag. SPEEDY 120 W – 500 Ω
Maximum output power monopolar coag. DEEP 120 W – 200 Ω
Maximum output power monopolar coag.  SPRAY 100 W – 2000 Ω
Maximum output power monopolar coag. SPRAY ARGON 100 W – 2000 Ω
Maximum output power bipolar  CUT 120 W – 50 Ω
Maximum output power bipolar cut-coag. CUT80% 120 W – 50 Ω
Maximum output power bipolar cut-coag. CUT60% 120 W – 50 Ω
Maximum output power bipolar cut-coag. CUT40% 100 W – 50 Ω
Maximum output power bipolar cut-coag. BLEND 120 W – 150 Ω
Maximum output power bipolar coag. COAG. 120 W – 50 Ω
Maximum output power bipolar coag. VESSEL SEALING 200 W – 50 Ω
Working frequency Monopolar / Bipolar 425 kHz / 525 kHz

Twin operative activity

  • Two output channels for monopolar cutting
  • Two independent setting and output channels for the most frequent monopolar coagulation

Controlled cutting procedures

  • Automatic power or TACS (Tissue Adaptive Contact System)
  • Enhanced cutting current for eschar free incision
  • Cutting current with selectable coagulating property for bleeding controlled dissection
  • Low capacitive coupling by slow BLEND current for endoscopic procedures

Twin controlled coagulative procedures

  • SPEEDY coagulation and DEEP coagulation available to two operators
  • SPRAY coagulation available by hand switch or foot switch controls

Wide bipolar features

  • Bipolar cutting current with selectable bleeding control
  • Slow BLEND cutting current
  • Separately activable Automatic Start/Stop coagulation
  • Vessel Sealing up to 7mm

Surgeon and patient total safety

  • Acceptability of contact impedance between patient body and return electrode continuously watched by Skin Plate Electronic Control (SPEC)
  • H.F. Leakage currents continuously monitored
  • Mains fluctuation automatically compensated before to start the delivery of HF power

Standard accessories

  • Disposable handle with switches
  • Reusable handle with switches
  • Blade electrode 7 cm
  • Blade electrode 16 cm
  • Needle electrode 7 cm
  • Ball electrode 6 cm
  • Cable for neutral electrode
  • Disposable split neutral electrode
  • Electrode cleaning sponge
  • Double water-proof foot-switch
  • Power supply cable 5 m
  • Cable for neutral electrode
  • Disposable split neutral electrode
  • Electrode cleaning sponge
  • Double water-proof foot-switch
  • Power supply cable 5 m

Optional accessories

  • Reusable handle without finger switches
  • Steel neutral electrode 16x24cm with cable 3m
  • Steel neutral electrode 16x24cm autoclave with cable
  • Cable for neutral plate
  • Bipolar Cable EU 3m
  • Twin Bipolar Cable 3m
  • Bipolar artery sealer forceps cable
  • Disposable Neutral electrode
  • Bipolar Artery Sealer 27cm TIP 3mm
  • Bipolar Artery Sealer 25,5cm TIP 3mm
  • Bipolar Artery Sealer 17cm TIP 2mm
  • Blade Curved Electrode 7 cm
  • Needle Curved Electrode 7 cm
  • Needle Electrode 13 cm
  • Ball Electrode Ø 2mm 6 cm
  • Ball Curved Electrode Ø 2mm 5 cm
  • Ball Electrode Ø 3mm 6 cm
  • Ball Curved Electrode Ø 3mm 5 cm
  • Ball Electrode Ø 3mm 13 cm
  • Ball Curved Electrode Ø 4mm 6 cm
  • Ball Electrode Ø 5mm 6 cm
  • Ball Curved Electrode Ø 5mm 6 cm
  • Ball Electrode Ø 5mm 14 cm
  • Loop Electrode10x10 l.14 cm
  • Loop Electrode20x13 l.14 cm
  • Loop Electrode20x20 l.15 cm
  • Conization Electrode 13 cm
  • Monopolar cable m4-f4
  • Monopolar cable m4-f2.8
  • Monopolar cable m4-mp4
  • Bipolar Forceps 11,5cm TIP0.5mm
  • Curved Bipolar Forceps 11,5cm TIP0.5mm
  • Bipolar Forceps 20cm TIP 1mm
  • Bipolar Forceps 20cm TIP 2mm
  • Curved Bipolar Forceps 20cm TIP 1mm
  • Curved Bipolar Forceps 20cm TIP 2mm
  • Angled Bipolar Forceps 20cm TIP 1mm
  • Angled Bipolar Forceps 20cm TIP 2mm
  • Angled Curved Bipolar Forceps 20cm TIP 1mm
  • Angled Curved Bipolar Forceps 20cm TIP 1mm
  • Bipolar Electrode 20cm
  • Monopolar Forceps 20cm TIP2mm
  • Monopolar Surgical Scissors 18cm
  • Conductive rubber neutral electrode
  • Conductive rubber split neutral electrode
  • Trolley 3 shelves wide
  • Trolley 5 shelves wide
  • Drawer for trolley